What was found
ON APU STARTUP, APU FAULT LIGHT ILLUMINATED. GROUNDED-YES. REF B737-800 FIM 49-40 TASK 802, FOUND NO NOISE COMING FROM IGNITER PLUG DURING START. R & R IGNITER PLUG, REF B737-800 AMM 49-41-51. R & R IGNITER UNIT, REF AMM 49-41-39. R & R IGNITER LEAD, REF AMM 49-41-52. STARTED APU, WITH NO DEFECTS NOTED. NO CURRENT FAULTS IN CURRENT STATUS. GROUND VERIFICATION SUCCESSFUL.