Service difficulty report · Bleed Valve · Boeing 737890

Difficulty date
August 26, 2021
Submitted
August 31, 2021
Operation
Air carrier
Aircraft
N564AS
Make and model
Boeing 737890
Aircraft serial
35103
Aircraft time
54,939 hours, 16,421 cycles
Part
Bleed Valve
Part number
32145526
Part serial
5708
Condition
Leaking
Location
Nr 2 Engine
Part time
62,849 hours, 25,972 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER ENG START, DUCT PRESSURE #2 DUCT INDICATED NORMAL POST. ENG START PRESSURE DURING CLIMB AFTER T/O, DUCT PRESSURE #2 INDICATED 5-10 PSI. (#1 WAS APPROX 40 PSI) A/C WAS PRESSURIZING NORMALLY. CLIMBING THROUGH 10,000 OR SO DUCT PRESSURE #2 POPPED UP TO APPROX. 40 PSI AND REMAINED AT NORMAL PRESSURE FOR REMAINDER OF FLIGHT. GROUNDED - YES. PERFORMED B737-800 AMM TASK 36-11-00-700-802 ENG BLEED AIR SYS LEAK CK WITH APU, FOUND PRSOV MANUAL OVERRIDE NUT WITH SOME PLAY AND HAS TOO MUCH LEAKAGE, REQUIRES R/R OF PRSOV. P DIAZ 77613. REMOVED & REPLACED #2 ENG PRSOV, REF MM 36-11-04-000-801 & MM 36-11-04-400-801. OPS CK GOOD. NO LEAKS NOTED.