What was found
5 MINUTES AFTER TAKEOFF R SIDE WINDOW OVERHEAT LIGHT ILLUMINATED. PER QRH TURNED OFF FOR 5 MINUTES, THEN BACK ON . OVERHEAT LIGHT ILLUMINATED AGAIN. GROUNDED - YES. PERFORMED B737-900 AMM 56-12-11-400-801 STEP 3.F.6-7, NEWLY INSTALLED WINDOW CODE H16, MOVED TAP POSITION TO POST 1 OF TB5014 REF B737-900 WDM 30-41-11 PG 3 SH 2. REPLACED NO. 2 SLIDER WINDOW PER AMM 56-12-11. WINDOW ADJUSTMENT IS COMPLETE PER AMM 56-12-11. WINDOW HEAT SYSTEM OPS TEST REF AMM 30-41-00-710-810 NORMAL. LEAK CHECK OF WINDOW GOOD.