What was found
APU QUIT AND TURNED FELL OFF. GROUNDED - YES. PER TECH SERVICES VERIFIED FAULT 49-41181 SHOW FROM STARTS 4 THRU 8. REMOVED PRECAUTIONARY AND REPLACED APU IGN PLUG AND APU IGN UNIT REF B737-800 AMM 49-41-31 AND 49-41-51 OPS TEST GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU QUIT AND TURNED FELL OFF. GROUNDED - YES. PER TECH SERVICES VERIFIED FAULT 49-41181 SHOW FROM STARTS 4 THRU 8. REMOVED PRECAUTIONARY AND REPLACED APU IGN PLUG AND APU IGN UNIT REF B737-800 AMM 49-41-31 AND 49-41-51 OPS TEST GOOD.