Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
February 5, 2022
Submitted
February 8, 2022
Operation
Air carrier
Aircraft
N533AS
Make and model
Boeing 737890
Aircraft serial
35201
Aircraft time
40,837 hours, 11,794 cycles
Part
Modulating Valve
Part number
3989085
Part serial
30448
Condition
Faulty
Location
Left Ecs Bay
Part time
13,718 hours, 4,191 cycles
Stage of operation
TX
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONT CAB ZONE TEMP LIGHT ILLUMINATED AFTER START. GROUNDED - YES. CONFIRMED CONT CAB ZONE TEMP LIGHT IS ON. PERFORMED B737-800 FIM 21-62 TASK 839. FOUND LIGHT ILLUMINATED ON TEMP CONTROLLER 2, FOR FLIGHT DECK TRIM VALVE. RESET AFTER VERIFY TEST. CONTINUED TO FIM 21-62 TASK 832. GOOD VOLTAGE AT CONNECTOR 03886. PER FIM REQUIRES REPLACEMENT OF " CONTROL CABIN TAV, V142." LOCATED IN LEFT ECS BAY. REMOVED & REPLACED LH TEMP CONTROL VALVE REF B737-800 AMM 21-51-10-400-801. OPS CHECK GOOD.