What was found
LH SIDE WINDOW OVERHEAT ILLUMINATED ON CLIMB OUT. RAN QRH 3.6 AND OVERHEAT LIGHT STAYED ILLUMINATED. GROUNDED - YES. FOUND LH SIDE WINDOW OVERHEAT LIGHT EXTINGUISHED, PERFORMED WINDOW HEAT CONTROL UNIT BITE PROCEDURE PER B737-800 FIM 30-41-00-810-801, BITE CHECK GOOD, NO ACTIVE FAULT, LH SIDE WINDOW OVERHEAT LIGHT REMAINS EXTINGUISHED.