What was found
LOWER EMERGENCY EXIT SIGN INOP AT ROW 17DEF. GROUNDED - YES. REF B737-900 WDM 33-51-21 FOUND CONNECTOR D3668 NOT FULLY SECURE. SECURED CONNECTOR D3668, EMERGENCY EXIT LIGHT SIGN OPS NORMAL REF B737-900 AMM 33-51-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.