What was found
CFM IS REPORTING #2 ENGINE ODMS CHIP COUNT INCREASE ON A SINGLE FLIGHT. GROUNDED - YES. PERF ODMS SENSOR INSP IAW B737-9 AMM 79-00-00. PARTICLES CANNOT BE VISUALLY IDENTIFIED, TO BE SENT TO LAB FOR IDENTIFICATION. ODMS BUILDUP IS NORMAL FUZZ LEVEL. PERF SCAVENGE SCREEN PLUGS INSP IAW AMM 79-21-04. NO DEBRIS FOUND ON ANY SCAVENGE SCREENS. PERF STARTER MAGNETIC CHIP DETECTOR INSP IAW AMM 80-11-09. FOUND ABNORMAL ACCUMULATION OF PARTICLES. AMOUNT OF PARTICLES IDENTIFIED IAW AMM 79-00-00, AMOUNT IS LIGHT MODERATE FUZZ. PARTICLES CANNOT BE VISUALLY IDENTIFIED R&R ENG #2 STARTER PER AMM 80-11-01/401. PERF DEBRIS MONITORING SYS B COUNT RESET REF AMM 71-00-00-700-802-G00 ALL TESTS PASS.