What was found
REF ASA TC#78273000 #1 ENG SHOWS SHORT TIME FAULT 73-11281, EEC CHANNEL IS NOT ENERGIZED WITH THE ALTERNATOR VOLTAGE. GROUNDED - YES. PER SEA TECH SVC RELOADED #1 ENG EEC SOFTWARE PER B737-800 AMM TASK 73-21-60-470-801-F00, SOFTWARE LOAD SUCCESSFUL. #1 ENGINE EEC TEST COMPLETED, NO FAULTS FOUND REF AMM TASK 73-21-00-700-804-F00. PERFORMED #1 ENGINE RUN REF AMM 71-00-00-700-801-F00 TEST 3A. NO DEFECTS NOTED. IDLE POWER LEAK CHECK. #1 ENGINE FAULT MSG 73-11281 NO LONGER SHOWS.