What was found
L-2 DOOR FLOOR CREASE BEAM AREA OF LIGHT CORROSION, MARKED. GROUNDED - YES. REMOVED DAMAGE L-2 DOOR FLOOR CREASE BEAM FOUND IN LIMITS IAW B737-700 SRM 53-70-15-1A-1.W= .050 O= .080 R= .077 L= .050 D= .003.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L-2 DOOR FLOOR CREASE BEAM AREA OF LIGHT CORROSION, MARKED. GROUNDED - YES. REMOVED DAMAGE L-2 DOOR FLOOR CREASE BEAM FOUND IN LIMITS IAW B737-700 SRM 53-70-15-1A-1.W= .050 O= .080 R= .077 L= .050 D= .003.