What was found
WHILE PERFORMING TC 78273000 FOUND #1 ENG SHORT TIME FAULT 73-21281 EEC CHANNEL IS NOT ENERGIZED WITH THE ALTERNATOR VOLTAGE ON FL 2 ONLY. GROUNDED - YES. (RESOLVED ON W/O: 1962079 TASKCARD: N/R-00001 ) PERFORMED FIM 73-27 TASK 805, FOUND FAULT DOES NOT SHOW ON #1 ENG. RECENT FAULTS, AND FAULT HISTORY SHOWS FOUND FAULT ONLY ON LEG 7. PER FIM, EEC TEST GOOD, NO FAULTS. NO HISTORY LAST 90 DAYS.THIS PLT DEFERRAL CLEARED.PLC C/N 140184678 RMVD.