As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
#1 ENG STARTER VALVE STAYED ILLUMINATED THEN FLASHED WHILE STARTING. GROUNDED - YES. ACCOMPLISHED ALT DEACTIVATION PROCEDURES. REVERSED ALT DEACTIVATION PROCEDURES REF MPM 5-07-01 TBL3 ITEM 9 G. BERGONIA 53561 07/22/2023. RMVD & RPLD #1 ENG START VALVE ASSY REF MM 80-11-03 (VERFIED BONDING CK GOOD PER SAME. P. BASSEN 91832) OPS CK'D #1 ENG START VALVE OPS NORMAL NO LEAKS NOTED REF LGPG 60496132 FOR COWLING OPEN/CLSING & ALT DEACT PROCEDURES.