What was found
DID NOT GET LIGHT OFF ON #2 ENG START. GOOD DUCT PRESSURE. HAD FUEL FLOW FOR 5-10 SEC - THEN WENT TO ZERO. IGNITION CB'S ALL IN. STARTED #2 ENG ON RIGHT IGNITION. GROUNDED - YES. REMOVED AND REPLACED # 2 ENGINE RIGHT IGNITER PLUG, IGNITION LEAD & RIGHT EXCITER ( LOWER ) REF. 74-21-02, 74-21-01 AND 74-11-01. GROUND VERIFICATION TEST NORMAL AMM 71-00-00-730-805-G00, 71-00-00 TEST 4. THIS CLEARS MEL 74-00-01C, C/N # 23023960 PLACARD REMOVED REVERSED MAINT. PROCEDURES. 2 C/B REMOVED AND RESET SEAMC CARL NOTIFIED.