What was found
#1 START SWITCH DID NOT CUTOUT AT 56 % N2 ON INITIAL START. GROUNDED - YES. T/S IAW FIM 80-07 TASK 808 & START SW RELEASE W/ C/B PULLED. S266 X1-DP3973B H4 - 2.2 OHMS. S266 X1-DP3975B H4 2.2 OHMS. S266 X1 - A/C GND - 1.9 MEGOHMS. FURTHER T/S SUSPECT #1 ENG START SWITCH. REMOVED AND REPLACED #1 ENG START SWITCH & OPS CK NML IAW AMM 80-11-00. CLEARS MEL 80-2B. PLACARDS REMOVED. SEAMC JOE. ENG STARTER C/O @ 55% N2.