What was found
#2 ENG EGT EXCEEDED 913 DEGREES C ON TAKE OFF FOR ABOUT 3 SECONDS. (REF TSR714984) GROUNDED - YES. (RESOLVED ON W/O: 1970040 TASKCARD: N/R-00001) INTERROGATED CDU FOR ENGINE EXCEEDANCE PAGE CHECK PER AMM 71-00-00-740-801-F00, FOUND # 2 ENG EGT EXCEEDANCE WAS 960 DEGREES C FOR 9 SECONDS, NO EXCEEDANCES FOR #1 ENG. C/W INSPECTION AFTER ENGINE OPERATIONS ABOVE THE LIMITS PER AMM TASK 71-00-00-800-804-F00, FOUND #2 ENG EGT EXCEEDANCE DURING TAKE OFF TO BE WITHIN AREA A OF FIGURE 603. PERFORMED VISUAL INSPECTION OF #2 ENGINE INLET & EXHAUST, NO DEFECTS FOUND. NO CURRENT ENGINE FAULTS LOGGED ON #2 ENG. FURTHER TROUBLE SHOOTING REQUIRED TO BE PLACED ON PLT DEFERRAL FOR 150 HOURS PER AMM 71-00-00-800-804-F00 STEP 6(B). SEAMC ARNIE NOTIFIED. C/N# 17068459 APPLIED.