What was found
DURING COMPLETION OF TC # 78472040 NO. 2 ENG CHIP DETECTOR INSP, FOUND BLACK PACKING DEBRIS IN SCAVENGE SCREEN OF FORWARD SUMP SCAVENGE MCD. GROUNDED - YES. REMOVED AND REPLACED PACKINGS ON INNER AND OUTER SPOOLS OF #2 EG AGB/TGB SCAVANGE, FWD SUMP SCAVANGE AND REAR SUMP SCAVANGE UP THROUGH AMM STEP 79-21-01-400-804-F00 4.G(6). P GARNER 43305 10-01-2023. COMPLETED IDLE POWER LEAK CHECK AND INSTALLATION OF APPLICABLE CHIP DETECTORS OF ENG 2 LUBE UNIT. LEAK CHECKS GOOD. REF AMM 79-21-01-400-804 -F00 STEPS G(7)-(9) THIS CLEARS PLT C/N 010334013. SEAMC AUSTIN NOTIFIED.