What was found
ENG 1 HYD PULP LOW PRESSURELT ILLUMINATED ELEC 2 HYD PUMPLOW PRESS LT ILLUMINATED IN 1 HR BEFORE LANDINGENG 2 HYD PUMP LOW PRESS LT ILLUMINATED, BUT EXTINGUISHED DECENDING ALT 18,000. GROUNDED - YES. REMOVED ENG 1 DRIVEN PUMP REF AMM 29-11-11.54204 10-22-2023. INSTALLED #1 HYDRAULIC DRIVEN PUMP PER AMM 29-11-11. Y-CHOY 79520. REQUIRES HYDRAULIC A&B FLUSHING. TASK 29-11-00-170-801. Y-CHOY 79520. PERFORMED HYDRAULIC A&B FLUSHING PER AMM 29-11-00-170-801.COMPLETED INSTALLATION TASK. OPS CHECK GOOD. NO DEFECTS NOTED. E JASSO 23718. OPENED MIG-2C 40-005320 CLOSED MIG-2C 40-005320. OPENED MIG-2C 40-0053204 CLOSED MIG-2C 40-0053204.