As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT WET AREA STA 986 FLOOR BEAM HAS AREAS OF CORROSION RBL 5 TO RBL 60. GROUNDED - YES. REMOVED DAMAGE WITH SURFACE BLEND FOUND TO BE OUT OF LIMITS REPAIRED STA 986 FLOOR BEAM IAW B737-800 SRM 53-70-51-2R-4W 1 O .150 R .090 L 1 D .060.