What was found
DURING GEAR RETRACTION ON TAKEOFF, NOSE GEAR EXTENDED AFTER MOVING GEAR HANDLE TO THE OFF POSITION. GEAR HANDLE FELT AS THOUGH IT MOMENTARILY SLIPPED OFF THE OFF DETENT. GEAR INDICATED NOSE GEAR DOWN AND GREEN, MAINS RETRACTED (NO LIGHTS). GEAR WAS CYCLED DOWN (3 GREEN), UP, & OFF. GEAR OPERATED NORMALLY. GROUNDED - YES. PERFORMED FIM 32-30 TASK 815 THROUGH STEP E. PERFORMED AMM 32-32-11-400-801G PER FIM STEP E(D), OPERATIONAL CHECK GOOD. NO ADDITIONAL ACTION REQUIRED. ACFT OK FOR SVC.