As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO R/H TRANSITION AFT OF DOOR HAS AREAS OF CORROSION GROUNDED - YES. REMOVED DAMAGE TRANSITION PANEL FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2, REMOVED AND REPLACED TRANSITION PANEL IAW SRM 53-00-53-2R-5 W:1" O:.040" R:.032 L:1" D:.008