What was found
EMERGENCY EXIT LIGHT COVER NEXT TO EXIT DOOR AT ROW 16 A/C RIGHT CAME OFF. GROUNDED - YES. (RESOLVED ON W/O: 2026423 TASKCARD: N/R-00001 ) REPLACED EMERGENCY EXIT SIGN AND LIGHT ASSEMBLY AT ROW 16 R/H SIDE. REF AMM 33-51-01. OP CHK GOOD. CLOSES PLT. SEAMC SCOTT NOTIFIED.