What was found
STA 947 FLOOR BEAM UPPER TEE CORRODED AT RBL-48. GROUNDED - YES. BLENDED CORROSION, FOUND TO BWE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1. REPAIRED FLOOR BEAM IAW B737-800 SRM 53-70-51-2R-5W= 1.0 O= .180 R= .150 L= 3.00 D= .030.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 947 FLOOR BEAM UPPER TEE CORRODED AT RBL-48. GROUNDED - YES. BLENDED CORROSION, FOUND TO BWE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1. REPAIRED FLOOR BEAM IAW B737-800 SRM 53-70-51-2R-5W= 1.0 O= .180 R= .150 L= 3.00 D= .030.