What was found
AFT WET AREA FLOOR STRAP AT STA 1016 LBL 3 HAS CORROSION. GROUNDED - YES. REMOVED & REPLACED AFT WET AREA FLOOR STRAP AT STA 1016 LBL 3 IAW B737-800 SRM 51-40-02-0G-0. W 1, O .071, R .059, L 1 1/12, D .018.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA FLOOR STRAP AT STA 1016 LBL 3 HAS CORROSION. GROUNDED - YES. REMOVED & REPLACED AFT WET AREA FLOOR STRAP AT STA 1016 LBL 3 IAW B737-800 SRM 51-40-02-0G-0. W 1, O .071, R .059, L 1 1/12, D .018.