What was found
FWD CARGO LEFT TRANSITION PANEL CORRODED STA 500D TO 500L. GROUNDED - YES. REMOVED DAMAGE, & FOUND TO BE OUT OF LIMITS. INSTALLED REPAIR PARTS AND RESTORED FINISH IAW SRM 53-00-53-2R-5.W=2 O= .040 R= .033 L=3 D= .007.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO LEFT TRANSITION PANEL CORRODED STA 500D TO 500L. GROUNDED - YES. REMOVED DAMAGE, & FOUND TO BE OUT OF LIMITS. INSTALLED REPAIR PARTS AND RESTORED FINISH IAW SRM 53-00-53-2R-5.W=2 O= .040 R= .033 L=3 D= .007.