What was found
FWD CARGO BAY, STRINGER 27L HAD CORROSION AT BS 540. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1. REPAIRED STRINGER IAW SRM 53-00-03-2R-1W =.650 O= .045 R= .002 L= 2.25 D= .043.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY, STRINGER 27L HAD CORROSION AT BS 540. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1. REPAIRED STRINGER IAW SRM 53-00-03-2R-1W =.650 O= .045 R= .002 L= 2.25 D= .043.