What was found
ANC - FLT 51 - PRIOR TO DEPARTURE, CREW REPORTED EMERGENCY EXIT LIGHTS ILLUMINATE WITH THE EMERGENCY LIGHT SWITCH IN 'OFF' ARM, OR 'ON' POSITIONS. REPLACED BATTERY PACK AT ROW 10 AND LIGHTS OPERATED NORMALLY. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ANC - FLT 51 - PRIOR TO DEPARTURE, CREW REPORTED EMERGENCY EXIT LIGHTS ILLUMINATE WITH THE EMERGENCY LIGHT SWITCH IN 'OFF' ARM, OR 'ON' POSITIONS. REPLACED BATTERY PACK AT ROW 10 AND LIGHTS OPERATED NORMALLY. (W)