What was found
SEA - DURING MAINTENANCE, THE L1 DOOR WAS FOUND TO BE HARD TO CLOSE. REMOVED DOOR. REPLACED UPPER DOOR GATE DUE TO INTERFERENCE FIT WITH DOOR FRAME. INSTALLED AND RIGGED DOOR. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEA - DURING MAINTENANCE, THE L1 DOOR WAS FOUND TO BE HARD TO CLOSE. REMOVED DOOR. REPLACED UPPER DOOR GATE DUE TO INTERFERENCE FIT WITH DOOR FRAME. INSTALLED AND RIGGED DOOR. (M)