What was found
DURING TRANSIT CHECK, THE MAINTENANCE PERSONNEL PERFORMED A BOROSCOPIC INSPECTION DETECTING BLADES TIP BENDED IN THE FIRST STAGE OF HIGH PRESSURE COMPRESSOR ROTABLE SECTION AND A IGV SCRATCHED IN THE RT ENG, OUT OF LIMITS IAW MM 72-00-00. THE RT ENG WAS REPLACED AND TESTED IAW MM 71-00-02 AND 71-00-00, ALL CORRECT.