What was found
DURING OVERNIGHT SERVICE, SLAT NR 5 CONTROL CABLE WAS DETECTED BROKEN. CONTROL CABLE WAS REPLACED IAW MM 27-80-00, TEST CORRECT. DURING OVERNIGHT SERVICE, LT WING OPERATIONAL TEST OF SLAT NR 5 WAS PERFORMED IAW MM 27-80-00, ALL CORRECT.