Service difficulty report · Connector · Doug DC982

Difficulty date
September 14, 2006
Submitted
September 15, 2006
Operation
Air carrier
Aircraft
N501AM
Make and model
Doug DC982
Aircraft serial
49188
Aircraft time
62,643 hours, 46,608 cycles
Part
Connector
Condition
Dirty
Location
Dual Hyd Valve
Part time
11,612 hours, 7,171 cycles
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT RETURNED TO PLATFORM DUE TO DURING TAXING AND AFTER RELEASING PARKING BRAKES, THE 4 ANTI-SKID LIGHTS TURNED ON. AT PLATFORM ANTI-SKID DUAL PRESS CONTROL VALVES CONNECTORS AND SWITCHES S1-130 AND S10-195 WERE CLEANED IAW MM 32-43-05. ANTI-SKID SYSTEM WAS TESTED IAW MM 32-43-00, ALL CORRECT. AS A PRECAUTIONARY ACTION DURING OVERNIGHT CHECK, BOTH DUAL PRESS CONTROL VALVES, RIGHT SIDE, WERE REPLACED IAW MM 32-43-00, TESTED CORRECT.

More about the Doug DC-9-82