What was found
ACFT RETURNED TO PLATFORM, AFTER ENGINES START, THE FLAP L/E TRANSIT LIGHT TURNED ON. MX PERSONNEL PERFORMED A BITE ON FSEU IAW MM 27-11-00, DETECTING THE SLAT 7 WITH FAILURE, FIM 27-88 TASK 803 PROCEDURE WAS PERFORMED, CONFIRMING THE FAILURE. DURING MX REVISION, THE SLAT 7 TARGET WAS OUT OF POSITION; SO THE SLAT 7 TARGET WAS REPOSITIONED IAW MM 27-81-21 PARAGRAPH 3, TESTED CORRECT.