What was found
DURING CLIMB, THE RT ENG VIBRATION REACHED 2.5 UNITS. ACFT WAS SENT TO THE HANGAR & MX PERFORMED REVISION TO CHIP DETECTOR IAW AMM 79-00-00, NO METAL PARTICLES WERE FOUND. A BORESCOPE INSPECTION TO LPT STAGES 1 - 3 IAW AMM 72-00-00, NO DAMAGES WERE FOUND. LUBRICATION OF THE FAN ROTOR BLADE OF THE RT ENG IAW AMM 72-21-02. TRIM BALANCE WAS PERFORMED IAW AMM 71-00-00 TASK 71-00-00-750-803-F00. VIBRATION SURVEY TEST NR 7 WAS PERFORMED IAW AMM 72-00-00, BEING WITHIN LIMITS.