Service difficulty report · Pump · Boeing 737852

Difficulty date
November 23, 2019
Submitted
January 22, 2020
Operation
Air carrier
Aircraft
N875AM
Make and model
Boeing 737852
Aircraft serial
36705
Aircraft time
21,296 hours, 7,909 cycles
Part
Pump
Part number
66087
Part serial
K2012
Condition
Failed
Location
Hyd System
Part time
41,828 hours, 19,925 cycles
Stage of operation
IN
How discovered
9
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CCM PERSONNEL REPORTED THAT AFTER LANDING AT PLATFORM, THE HYDRAULIC PUMP LOW PRESSURE LIGHT FOR RH ENGINE TURNED ON; SO MAINTENANCE PERSONNEL PERFORMED CONDITIONAL INSPECTION DETECTING CASE DRAIN NOSE INCORRECT INSTALLED AND HYD PUMP LOOSED DUE TO INCORRECT TORQUE, SO MAINTENANCE PERSONNEL PERFORMED REPLACEMENT OF ENGINE DRIVE PUMP NO. 2 IAW AMM 29-11-11-400-801, TEST CORRECT.