Service difficulty report · Trunnion Pin · Cndair CL6002C10

Difficulty date
October 20, 2008
Submitted
October 24, 2008
Operation
Air carrier
Aircraft
N712EV
Make and model
Cndair CL6002C10
Aircraft serial
10074
Aircraft time
14,900 hours, 9,932 cycles
Part
Trunnion Pin
Condition
Corroded
Location
Rt Mlg
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT MLG SHOCK STRUT UPPER (FWD) ATTACHMENT TRUNNION PIN SHOWS SIGN OF CORROSION. AFTER FURTHER INSPECTION FOUND RESIDUE TO BE DRIED CORROSION INHIBITING COMPOUND. REMOVED BOLT, CLEANED AREA AND REINSTALLED BOLT WITH CORROSION INHIBITING COMPOUND PER AMM 32-00-05. RII SATISFACTORY FOR THE INSTALLATION OF THE FWD TRUNNION PIN ATTACH BOLT PER CRJ 700 AMM 32-11-05 AND SP 607.