As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN AVIONICS BAY FLOORBOARD SUPPORT ANGLE ATTACHED TO AFT SIDE OF FS 280 FRAME HAS CORROSION DAMAGE (MARKED). REMOVED AND BLENDED AVIONICS BAY FLOORBEAM ANGLE. BLENDED OUT OF LIMITS PER SRM 51-21-06. TRANSFERRED HOLES FROM OLD ANGLE TO TEMPLET AND FROM TEMPLET TO NEW SUPPORT ANGLE IAW SRM 51-40-11. RIVETED NEW ANGLE IN PLACE USING SOLID RIVETS AND LOCK FASTENERS IAW SRM 51-42-06 AND 51-42-20.