What was found
LT 280 FLOORBEAM, UPPER SURFACE HAS MINOR CORROSION. REMOVED SURFACE CORROSION ON LT 280 FLOORBEAM, UPPER SURFACE PER SRM 51-12-00. PERFORMED UT THICKNESS MEASUREMENT OF BLEND AREA ON LEFT 280 FLOORBEAM IAW NDTM 51-20-004.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT 280 FLOORBEAM, UPPER SURFACE HAS MINOR CORROSION. REMOVED SURFACE CORROSION ON LT 280 FLOORBEAM, UPPER SURFACE PER SRM 51-12-00. PERFORMED UT THICKNESS MEASUREMENT OF BLEND AREA ON LEFT 280 FLOORBEAM IAW NDTM 51-20-004.