What was found
FS 409+128 VERTICAL POST BL 0.0 RT SIDE FWD FLANGE FIRST FASTENER AFT SIDE HAS A INDICATION NOTED APPROX .2 INCH IN LENGTH 100 PERCENT FSH FAILED NDT INSP. REMOVED DAMAGED VERTICAL POST AT FS 409+128 BL 0 PER SRM 51-42-06 AND 51-42-21. FABRICATED REPLACEMENT POST AND REINFORCEMENT ANGLE IAW SRM 51-24-21. REF DWG 601R32208. INSTALLED IAW EC/TC REO 601R-53-41-1056 AND SRM 51-42-06.