What was found
CARGO ENTRY FLOOR EDGE MEMBER HAS CORROSION AROUND NUTPLATE HOLES. REMOVED CARGO DOOR SILL PLATE IAW SRM 51-42-06, 51-42-21 AND 51-42-13, FOUND DOOR SILL TO BE OUT OF LIMITS IAW SRM 53-61-23. FABRICATED CARGO BAY FLOOR SILL USING 2024-T3 .050 PO NR W3776 IAW PART REMOVED IAW REO 601R-53-61-1574 REV A, ASA EC/TC REO 6014R-53-61-1574, STEP 2. COMPLIED WITH STEP 6 OF ASA EC/TC REO 601R-53-61-1574. PERFORMED EDDY CURRENT OF CARGO FLOOR SILL PLATE CUTLINE IAW NDTM 51-20-06. NO INDICATIONS NOTED. INSTALLED SILL PLATE AND DOUBER. C/W ALL STEPS OF EC/TC REO 601R-53-61-1574.