What was found
AFT CARGO DOOR, FLOOR SUPPORT SILL FOR 281JLF HAS CORROSION. BLENDED CORROSION REF SRM 53-61-23-001-001-A01. UT THICKNESS TEST REF NDTM 51-20-004. MEASUREMENTS RANGED .062-.070" IN BLENDS, ALL READINGS MARKED ON PART, PERFORMED EPT INSP ON AFT CARGO DOOR FLOOR SUPPORT SILL BLEND OUT, IAW NDTM 53-00-000, NO DEFECTS NOTED. FINISH RESTORED IAW SRM 51-21-16-001-001-A01. APPLIED CORROSION INHIBITING COMPOUD IAW SRM 51-21-11-001-001-A01.