What was found
CORROSION ON FLOOR SUPPORT AT LBL 9 BETWEEN FS 469-597 MULTIPLE LOCATION COMING FROM UNDER SEAT TRACK. CUT LINE ON NEW PARTS REQUIRE NDT IAW REO 670-53-00-029. PERFORMED EDDY CURENT INSP OF CUT LINES ON NEW PARTS IAW REO 670-53-00-029 IAW NDTM PART 1, NO INDICATIONS NOTED. PRIMED & PAINTED CUT LINES & FABRICATED PARTS IAW REO 670-53-00-0029 FABRICATED CLEATS IAW REO 670-53-00-278, INSTALLED LBL 9 FLOOR SUPPORT 485-565 IAW REO 670-53-00-29 FIG 13 PRIMED AND PAINTED IAW SRM 51-21-16. 4 EA NUTPLATES, INSTALLED 4 EA NUTPLATES AT AFT END OF SUPPORT FS 565 IAW SRM 51-45-00-001-001-A01.