What was found
PANEL 622CB CHAFED ON L/E (MARKED) RESOLVED ON W/O: 173017 TASKCARD: N/R-00312. BLENDED OUT CHAFING ON L/E PANEL 622CB ALL WORK DONE IAW CRJ700 SRM 57-12-00-001-001-A01. BLENDED AREA REQUIRE NDT. RECEIVED NEW PANEL, LOCATED HOLES AND TRIMMED IAW CRJ700 SRM 51-40-11-001-001-A01, 51-34-36-001-001-A01. NEW PANEL AWAITING ADR FOR PILOT HOLES, LOCATED HOLES NEED TO BE COUNTERSUNK. COUNTERSUNK SCREW HOLES IAW CRJ700 SRM 51-40-11-001-001-A01, INSTALLED DOUBLE FLUSH RIVET IN DOUBLE DRILLED HOLE IAW REO 670-57-41-196 AND CRJ700 SRM 51-42-06-001-001-A01, REFINISHED PANEL IAW CRJ700 SRM 51-25-01-001-001-A01. REFER M212 PANEL 622CB PG 61 FOR INSTALLATION. AWAITING EC/TC. CR 161779 10/02/10 (LH 10/06/10) RECEIVED EC/TC REO 670-57-41-196 REV RW 161752 10/06/10 (LH 10/06/10) ASA RII BD 5500008 161723 10/06/10 .