As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND ON FRAME FS 319.70 AT STR 27. REMOVED CORROSION. REPAIRED AREA FOUND TO BE WITHIN LIMITS IAW SRM 53-21-06-101-002-A01 AND 51-12-00-001-001-A01. PERFORMED FLUORESCENT LIQUID PENETRANT INSP ON REPAIR AREA FS 319.70 AT STR27 IAW SRM 51-12-00-001-001-A01 AND NDT INSP PROCEDURES PT-1. NO INDICATIONS NOTED AT THIS TIME. MINOR REPAIR.