What was found
FLOORBEAM STRUCTURE AT FS 589.0 OTBD IS CRACKED AT CARGO DOOR SEAL PLATE. R & R FLOORBEAM AT FS 589 IAW SRM 51-42-06 AND 51-42-21. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM STRUCTURE AT FS 589.0 OTBD IS CRACKED AT CARGO DOOR SEAL PLATE. R & R FLOORBEAM AT FS 589 IAW SRM 51-42-06 AND 51-42-21. MAJOR REPAIR.