What was found
PRESSURE FLOOR DOUBLER CORRODED AFT OF FS 439.00 RBL43. APPEARS TO BE 10F6 UNDOCUMENTED DOUBLERS INSTALLED ON PRESSURE FLOOR. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS OF BLEND AREA IAW MAC NDT INSPECTION PROCEDURE UT-3, MINIMUM MATERIAL REMAINING IS .048". R & R DAMAGED DOUBLER IAW REO 601R-53-41-316.