Service difficulty report · Priority Valve · Cndair CL6002B19

Difficulty date
October 1, 2011
Submitted
October 5, 2011
Operation
Air carrier
Aircraft
N873AS
Make and model
Cndair CL6002B19
Aircraft serial
7549
Aircraft time
22,762 hours, 20,084 cycles
Part
Priority Valve
Condition
Failed
Location
Mlg
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON DEPARTURE RECEIVED GEAR UP DISAGREE WARNING RAN QRH, DIVERTED. EMERGENCY DECLARED AS A PRECAUTION. R & R MLG PRIORITY VALVE IAW AMM 32-32-15 AND IPC 200 32-32-15 ITEM 245. R & R MLG SELECTOR VALVE IAW AMM 32-32-10. OPS & LEAK CHECKED GOOD IAW EA AMM. EXTENTION AND RETRACTION OF LANDING GEAR IS WITHIN LIMITS REF AMM 32-30-00, OPS CHECKED GOOD.