What was found
RT FS 280.00 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. MATERIAL REMOVED 0.002" LESS 10 PERCENT IN LIMITS. PERFORMED LPI TYPE1 METHOD C ON BLEND AREA IAW SRM 51-12-00-001-001-A01 IAW MAC NDT PROCEDURE PT-1. NO INDICATIONS NOTED. RESTORED FINISH AS NEEDED AT REPAIR AREA IAW SRM 51-42-06-001-001-A01 AND SRM 51-21-11-001-001-A01.