As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO BAY , LT FLOOR SILL SCREW HOLES CORRODED FROM FS 1051.3 TO 1088.2. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. PERFORMED UT THICKNESS INSPECTION OF BLENDED AREA IAW MAC NDT INSPECTION PROCEDURE UT 3. MIN MATERIAL REMAINING IS .061" ORIGINAL IS .063" MATERIAL, REMOVED IS .002". REPAIRED IAW REO 670-53-61-871.