As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT SIDE FLOOR SILL FROM FS 280 TO 319.70 HAS AREAS OF CORROSION AND IS BENT AT FS 319.70. REMOVED SILL PLATE IAW SRM 51-42-06-001-001-A01. LOCATED AND DRILL NEW SERVICEABLE PART IAW SRM 51-40-11-001-001-A01. INSTALLED NEW SERVICEABLE FLOOR SILL FROM FS 280.00 -FS 319.70 IAW SRM 51-42-06-001-004-A01.