As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT OVER WING EXIT FAILED FUNCTIONAL CHECK AT 60 POUNDS OF PULL. RT OVERWING EXIT FUNCTIONAL TEST GOOD IAW CH 52-21-00-720-801. COMPLIED WITH POWER ON FUNCTION CHECK OF RT OVERWING EXIT OPS CHECKED OK, PULL FORCE AT 38 NR , (LIMIT 30 +- 10) SPB 88079 12/26/12 IAW TASK 52-21-00-720-801.