As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SERVICE DOOR CUTOUT SILL CORRODED AT MULTIPLE LOCATIONS. REMOVED CORRODED MOUNTING ANGLE IAW SRM 51-42-06-001-001-A01. OBTAINED AND DRILLED NEW MOUNTING ANGLE AS RQUIRED IAW SRM TASK 51-40-11-001-001-A01. INSTALLED MOUNTING ANGLE, PN SH670-31996-3 ON SERVICE DOOR LOWER SILL IAW SRM 51-4206-001-001-A01.